Maintenance, replication and growth in microplates
Contact us
Maintenance, replication and growth in microplates
Contact us
  • Home
  • All products
  • About us
  • Protocols/Information
    • How we work
    • Maintenance, sterilisation and use of sandwich covers
    • Quality and reproducibility
    • Cultivation of CHO- and HEK cells
    • Literature
    • Relevant patents
    • Privacy statement
  • Hydrodynamics/OTR
    • Hydrodynamics/OTR recommendations and background
    • Videos 6-deepwell MTP
    • Videos 24-square deepwell MTPs
    • Videos 24-roundwell MTPs
    • Videos 24-hitplates
    • Videos 96-half deepwell MTPs
    • Videos 96-square deepwell MTPs
    • Videos 96-roundwell MTPs
    • Table Oxygen transfer rates
    • graphs OTRs in 96-squarewell MTPs
    • graphs OTRs in 24-squarewell MTPs
  • Sandwich Covers
    • Three classes of sandwich covers
    • Functions & use of sandwich covers
    • Sandwich covers for 2 & 6-well MTPs
    • Sandwich covers for 24-well MTPs
    • Sandwich covers for 96-well MTPs
    • Other sandwich covers
    • Robot-friendly covers
    • Background on robot-friendly covers
    • Disposable sandwich covers
    • Table evaporation rates
  • Clamp Systems
    • Functions & use of clamp systems
    • Clamps for deepwell MTPs only
    • Universal clamps for all MTPs
    • Robot-friendly clamps
  • Microplates
    • Basic information on plastics
    • 2 & 6 well microplates
    • 24 well microplates
    • 96 well microplates
    • Polystyrene microplates
    • Plates with transparant bottoms (Growth Profiler)
    • All microplates
  • Replicator and Press
    • Functions & use of replicators
    • All replicators & press
  • Growth Profiler
    • Growth Profiler
    • Specifications
    • How does it work
    • Robotic handling
    • Cited by
Categories
  • All
  • 24-well microplates
  • 6-well microplates
  • 96-well microplates
  • Clamps
  • Deepwell MTPs clamps
  • Microplates
  • Replacement parts
  • Replicators and Press
  • Sandwich covers
  • Sandwich covers for 24-well plates
  • Sandwich covers for 6-well plates
  • Sandwich covers for 96-well plates
  • Universal clamps
CR1200: Sandwich cover with no holes in the silicone layer
  • Solid silicon layer of 5mm thick with no holes
  • Available with silicon or butylrubber
Information and orders
CR1206: Sandwich cover for 6-deepwell MTPs
  • For 6-deepwell MTPs CR1406
  • Holes with a 7mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 20 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 400 µl/well/day
Information and orders
CR1206a: Low-evaporation sandwich cover for 6-deepwell MTPs
  • For 6-deepwell MTPs CR1406
  • Holes with a 4mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO cells)
  • Exchange of headspace air: 6.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 130 µl/well/day
Information and orders
CR1224: Sandwich cover for 24 deepwell MTPs
  • For all 24-deepwell MTPs
  • Holes with a 2.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 2.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 50 µl/well/day
Information and orders
CR1224a: Low-evaporation sandwich cover for 24-deepwell MTPs
  • For all 24-deepwell MTPs
  • Holes with a 1.2mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.7 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 16 µl/well/day
Information and orders
CR1224b: Sandwich cover with pins for 24-deepwell MTPs
  • For 24-deepwell MTPs with cavaties, such as CR1424cl
  • Holes with a 2.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 2.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 50 µl/well/day
Information and orders
CR1224c: Low-evaporation sandwich cover with pins for 24-deepwell MTPs
  • For 24-deepwell MTPs with cavaties, such as CR1424cl
  • Holes with a 1.2mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.7 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 16 µl/well/day
Information and orders
CR1224d: Sandwich cover for 24-deepwell MTPs
  • For all 24-deepwell MTPs
  • Holes with a 2.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 2.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 50 µl/well/day
Information and orders
CR1224e: Low-evaporation sandwich cover for 24-deepwell MTPs
  • For all 24-deepwell MTPs
  • Holes with a 1.2mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.7 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 16 µl/well/day
Information and orders
CR1224f: Sandwich cover with pins for 24-deepwell MTPs
  • For 24-deepwell MTPs with cavaties, such as CR1424cl
  • Holes with a 2.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 2.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 50 µl/well/day
Information and orders
CR1224g: Low-evaporation sandwich cover with pins for 24-deepwell MTPs
  • For 24-deepwell MTPs with cavaties, such as CR1424cl
  • Holes with a 1.2mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.7 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 16 µl/well/day
Information and orders
CR1224h: Sandwich cover for extra high 24-deepwell MTPs from HJ-Bioanalytik
  • For CR1424hd MTPs
  • Holes with a 2.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 2.5 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 50 µl/well/day
Information and orders
CR1224i: Low-evaporation sandwich cover for extra high 24-deepwell MTPs from HJ-Bioanalytik
  • For CR1424hd MTPs
  • Holes with a 1.2mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.7 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 16 µl/well/day
Information and orders
CR1224t: CO2-release sandwich cover for 24-deepwell MTPs
  • For all 24-deepwell MTPs
  • Holes with a 0.1mm diameter (FEP tubes)
  • Suitable for anaerobic cultivation
  • Exchange of headspace air: 0.004 ml / minute
Information and orders
CR1296: Sandwich cover for 96-deepwell MTPs
  • For all 96-deepwell MTPs
  • Holes with a 1.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 1 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 22 µl/well/day
Information and orders
CR1296a: Low-evaporation sandwich cover for 96-deepwell MTPs
  • For all 96-deepwell MTPs
  • Holes with a 0.8mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.3 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 8 µl/well/day
Information and orders
CR1296b: Sandwich cover with pins for 96-deepwell MTPs
  • For 96-deepwell MTPs CR1496a only
  • Holes with a 1.5mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 1 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 22 µl/well/day
Information and orders
CR1296c Low-evaporation sandwich cover with pins for 96-deepwell MTPs
  • For 96-deepwell MTPs CR1496a only
  • Holes with a 0.8mm diameter
  • Suitable for longer cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.3 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 8 µl/well/day
Information and orders
CR1296t: CO2-release sandwich cover for 96-deepwell MTPs
  • For all 96-deepwell MTPs
  • Holes with a 0.075mm diameter (PEEK tubes)
  • Suitable for anaerobic cultivation
  • Exchange of headspace air: 0.003 ml / minute
Information and orders
CR1306: Sandwich cover for 6-lowwell MTPs
  • For 6-lowwell MTPs
  • Holes with a 1.5mm diameter
  • Exchange of headspace air: 1 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 22 µl/well/day
Information and orders
CR1324: Sandwich cover for 24-lowwell MTPs
  • For 24-lowwell MTPs
  • Multiple formats available: check product page
Information and orders
CR1384: Sandwich cover for 384-well MTPs
  • For 384-well MTPs
  • Holes with a 0.6mm diameter
  • Due to surface tension, OTR may be low (non-specified)
Information and orders
CR1396b: Standard sandwich cover with pins for Enzyscreen 96-half-deepwell MTPs
  • For our polystyrene 96-half-deepwells such as CR1496c and CR1496dg
  • Holes with a 0.8mm diameter
  • Exchange of headspace air: 0.3 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 8 µl/well/day
Information and orders
CR1524: Sandwich cover for polystyrene 24-lowwell MTPs from Corning
  • For 24-lowwell MTPs from Corning
  • Holes with a 1mm diameter
  • Suitable for shorter cultivations (1-5 days)
  • Exchange of headspace air: 1.1 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 30 µl/well/day
Information and orders
CR1524a: Low-evaporation sandwich cover for polystyrene 24-lowwell MTPs from Corning
  • For 24-lowwell MTPs from Corning
  • Holes with a 0.2mm diameter in a stainless steel foil
  • Suitable for longer  cultivations (4+ days, e.g. CHO-cells)
  • Exchange of headspace air: 0.25 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 6 µl/well/day
Information and orders
CR1596: Sandwich cover for polystyrene 96-lowwell MTPs
  • For 96-lowwell MTPs with holes in between the wells
  • Holes with a 0.2mm diameter in a stainless steel foil
  • Exchange of headspace air: 0.25 ml / minute
  • Evaporation rate (30ºC, 50% humidity): 6 µl/well/day
Information and orders
© 2002–2025
General
  • Home
  • All products
  • About us
Information
  • Protocols/Information
  • Hydrodynamics/OTR
  • Sandwich Covers
  • Clamp Systems
  • Microplates
  • Replicator and Press
  • Growth Profiler